Manual of software and hardware of water controller


Manual


Document status


Document number


Instruction manual for the water control system


Draft


[√] Published


Modifying


Compiled

SYX


Date of compilation

2021-08-30


Level of confidentiality


Document version

1.0


The water controller is widely used in the boiling water room, bathhouse, apartment and other internal water use occasions of campuses, enterprises and government agencies, which can realize simple and convenient installation and water consumption control, realize the electronic and intelligent transaction and settlement, and improve the user's management efficiency and management means, which is the most important component of the campus and enterprise card. It has the advantages of small size, low power consumption, long life, perfect function, anti-theft water, power-off valve, etc., and adopts copper body with high temperature resistance.


Working principle and composition


IC card water controller is the latest high-tech mechatronics intelligent water controller developed by our company, with advanced microcomputer control technology as the core, IC card technology as the information transmission medium and composed of a highly intelligent instrument. It integrates the functions of controlling the flow of water and intelligent billing, and has the characteristics of accurate measurement, reliable performance, compact and reasonable structure.


The water controller adopts advanced electronic flowmeter metering, and is equipped with a new type of solenoid valve valve with low power consumption and fast on/off valve speed, and a microcomputer controller. Advanced logical encryption technology is used to implement one table and multiple cards to ensure the safety and reliability of user data. The use of the product completely solves the problem of public water in the school, and the traditional water use mode has changed from an average share to a more reasonable use mode of taking water and deducting fees, which greatly facilitates the school's management of reasonable water use for students.


3. Main features


1. Split full waterproof design, easy to install, simple and anti-theft and anti-destructive;


2. It is equipped with a six-point to four-point slipknot, which can be installed and easy to install


3. Charge according to the flow rate, accurate measurement, multi-use and multi-giving, and humanized charging


4. Solenoid valve switch, turn off the water in time when the power is off to avoid the waste of hot water;


5. Digital tube display, clearly display the balance, machine number, total consumption and date in the card (unique to the limited function);


6. Using imported chips, the program is stable and reliable, and the data is not lost when the power is off


7. You can choose offline or connected to the computer to recharge the operation, the offline recharge is simple and easy to operate, and the total amount of recharge can also be queried; Connect to a computer to query the detailed recharge report.


8. For schools or units that have already installed other systems (using Philips Mifare One card), this system can be compatible with the original card, and there is no need to purchase a new card to realize the "all-in-one card" function.


1. Software login and use


Open the system login screen,


As shown below:


Step 1


Water control software installation package


Step 2


Step 3


Step 4


Note: Install the D drive


Step 5


Step 6


Step 7


The software has been installed


Step 8


This shortcut appears on your computer's desktop


Step 9


Open the software, you need to provide the authorization number of the supplier, enter it to enter the system


Step 10


Step 11


Step 12


Enter the 8-digit system password:1
2345678


Step 13


Step 14


Step 15


Set the rate to 1 in this figure
0
Yuan per cubic meter


Step 16


The user issues a card


Step 17


Card issuance and recharge


2. Pictures and descriptions of the hardware of the water controller


+ Physical diagram of water controller:


2. Installation instructions and precautions for water controller


Please pay attention to the direction of the water inlet when installing;


When installing, please try to place the all-in-one machine horizontally, so as to avoid inaccurate billing and excessive pressure and unable to close the valve;


It can be used in both cold and hot water environments;


For the first time, please swipe the system card and setting card after booting up;


Wiring requirements: strong current and weak points are routed separately, and the distance should not be less than 30cm;


3. Technical parameters of water controller

卡片种类: Mifare S50;CPU:1208-10


Operating voltage: 12VDC;


Quiescent current: <100MA;


Maximum working current: <1.2A;


Control valve voltage: 12VDC;


Dosing accuracy: 1/550 liter;


Display: 6-digit LED backlit display;


READING DISTANCE: <5CM;


Card operation time: <0.3S;


Number of cards issued: unlimited;


Billing accuracy: 0.01 yuan/ton;


Fourth, the first use and setting of the water controller


4.1 Swipe the system card


Swipe the system card in the card swiping sensing area, and the screen of the water controller will display: "-SYS-", as shown in the following figure:


You can remove the card until the following prompt appears on the screen, as shown below


4.2 Swipe rate card


After swiping the system card, the screen of the water controller displays: "OPErr", as shown in the following figure:


Swipe the rate card in the card sensing area, and the screen prompts "PASS", as shown in the following figure:


5. The water controller is in normal use


5.1 Real-time flow metering mode


When the user uses it, put the card in the card swiping induction area, the water controller displays the card balance and opens the valve, the water is discharged, and the water is stopped when the card is opened.


5.2 Metering flow mode


When the user uses it, put the card in the card induction area, the water controller displays the card balance, deducts the amount once, and opens the valve to discharge the water.


6. Schedule


Fault phenomenon


The cause of the failure occurs


How to deal with it

SYSErr


System card not flashed (V2.0)


Swipe the system card


Chang Xian n. XXXX


System card not flashed (V3.0)


Swipe the system card

OPErr


The setup card has not been swiped


Swipe the settings card


Swiping is unresponsive

FM1701坏


Return to the factory for repair

Err17、34

FM1701坏


Return to the factory for repair

Err20


It is not a user card of this system


Replace or re-swipe the system card corresponding to the card

Err21


The setup card is not the same system as the system card


Redo the system card and the setting card

Err22、23、24、25


There was an error with the data on the card


to the software repair card

Err26


The card balance is insufficient


Add money to your card

Err27


The amount on the card is too large


Modify the card amount

Err30


There was an error writing the card


Re-swipe the card

Err35


Exceeding the daily limit


Only the machine with a limited number of days has a function

Err41


There is no traffic signal


There is no water coming out or the flow meter is broken


7. Instructions for installation and use (please be sure to read carefully)


1. The integrated water controller part only needs to connect the two ends to the pipe


2. The newly installed pipeline must be cleaned of sand, sediment, hemp and other slags in the pipeline before installation, so as not to cause the failure of the water controller.


3. The specifications of the water controller should be based on the common flow rate, and the diameter of the water meter cannot be determined by the pipe diameter alone. The water controller should not be used to introduce corrosive liquids. And the cold water meter is forbidden to enter hot water.


4. The water controller should be installed indoors as much as possible, and the direction of the arrow on the case must be consistent with the direction of water flow during installation. The installation location of the water meter should avoid exposure to the sun and rain, and it is convenient to disassemble and observe the place, and measures should be taken to keep warm in the cold winter.


5. The normal working environment temperature of the water controller is above 0 °C, and before the arrival of winter and in cold areas, the water meter use and management department must do a good job of anti-freezing of the water meter. All water meter damage, water outage, water leakage and other related losses caused by water stop and water leakage (such as water leakage soaking floor, furniture, electrical equipment, etc.) caused by improper installation or use of water meter or pipe nut, water pipe rupture, water meter freezing, freezing, etc. shall be borne by the water meter manager and the user, and the product supplier and manufacturer shall not assume any responsibility.